University of Cape Coast Institutional Repository

Groundwater Quality and Septic Tank Interaction: an Assessment of Health Implication in Amamoma, Cape Coas

Show simple item record

dc.contributor.author Mensah, Joanna Awortwe
dc.date.accessioned 2023-11-27T10:01:13Z
dc.date.available 2023-11-27T10:01:13Z
dc.date.issued 2022-12
dc.identifier.uri http://hdl.handle.net/123456789/10332
dc.description ii,ill:101 en_US
dc.description.abstract Groundwater is the globe's largest and greatest vital source of potable fresh water. It provides drinking water to billions of people and is used to irrigate the majority of the global food supply. In spite of its importance and availability, groundwater is mostly polluted globally. Despite the fact that water from boreholes can be contaminated through different means, the most widely recognized reason for contamination is owing to its closeness of septic tanks. The central purpose main for this research is to assess groundwater interaction with septic tank and its health implications on residents of Amamoma community who is a resident of the community understudy. Structured questionnaire, laboratory test and in-depth interview guide were used to obtain data from residents and assembly man for the community. Forty-two water samples (42) were collected from seven selected groundwater sites in Amamoma. Sample of water was tested six-times period to examine quality using standard analytical procedure. Questionnaires were also administered to residents of Amamoma who use groundwater. The Assemblyman of the community was interviewed his views on the groundwater quality and water related diseases. The results showed that all the seven well contained high levels of total coliform, faecal coliform and E-coli, beyond the WHO recommended levels. It was further revealed that the shorter the distance between septic tank and groundwater sources, the higher the microbial load. As a result, the two most prevalent sanitation-related diseases in the community are diarrhoea and typhoid fever, with children being more vulnerable to suffer from such diseases. It is recommended that Community Water and Sanitation Agency should periodically track and offer remediation to improve the quality of water sources en_US
dc.language.iso en en_US
dc.publisher University of Cape Coast en_US
dc.subject Contamination en_US
dc.subject Groundwater en_US
dc.subject Sanitation-related diseases en_US
dc.subject Septic tank en_US
dc.title Groundwater Quality and Septic Tank Interaction: an Assessment of Health Implication in Amamoma, Cape Coas en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search UCC IR


Advanced Search

Browse

My Account