University of Cape Coast Institutional Repository

Implementation of compensator-based intensity modulated radiotherapy with a conventional telecobalt machine using missing tissue approach

Show simple item record

dc.contributor.author Tagoe, S.N.A
dc.contributor.author Mensah, S.Y
dc.contributor.author Fletcher, J.J
dc.date.accessioned 2019-01-21T11:34:04Z
dc.date.available 2019-01-21T11:34:04Z
dc.date.issued 2018-12
dc.identifier.issn 1898-0309
dc.identifier.uri http://hdl.handle.net/123456789/3474
dc.description Article en_US
dc.description.abstract Objectives: The present study aimed to generate intensity-modulated beams with compensators for a conventional telecobalt machine, based on dose distributions generated with a treatment planning system (TPS) performing forward planning, and cannot directly simulate a compensator. Materials and Methods: The following materials were selected for compensator construction: Brass, Copper and Perspex (PMMA). Boluses with varying thicknesses across the surface of a tissue-equivalent phantom were used to achieve beam intensity modulations during treatment planning with the TPS. Beam data measured for specific treatment parameters in a full scatter water phantom with a 0.125 cc cylindrical ionization chamber, with a particular compensator material in the path of beams from the telecobalt machine, and that without the compensator but the heights of water above the detector adjusted to get the same detector readings as before, were used to develop and propose a semi-empirical equation for converting a bolus thickness to compensator material thickness, such that any point within the phantom would receive the planned dose. Once the dimensions of a compensator had been determined, the compensator was constructed using the cubic pile method. The treatment plans generated with the TPS were replicated on the telecobalt machine with a bolus within each beam represented with its corresponding compensator mounted on the accessory holder of the telecobalt machine. Results: Dose distributions measured in the tissue-equivalent phantom with calibrated Gafchromic EBT2 films for compensators constructed based on the proposed approach, were comparable to those of the TPS with deviation less than or equal to ± 3% (mean of 2.29 ± 0.61%) of the measured doses, with resultant confidence limit value of 3.21. Conclusion: The use of the proposed approach for clinical application is recommended, and could facilitate the generation of intensity-modulated beams with limited resources using the missing tissue approach rendering encouraging results. © 2018 Samuel N. A. Tagoe et al., published by Sciendo 2018. en_US
dc.language.iso en en_US
dc.publisher Sciendo en_US
dc.subject telecobalt machine, bolus en_US
dc.subject compensator; Gafchromic film, intensity modulated en_US
dc.title Implementation of compensator-based intensity modulated radiotherapy with a conventional telecobalt machine using missing tissue approach en_US
dc.title.alternative The Journal of Polish Society of Medical Physics Vol 24, Issue 4 en_US
dc.type Article en_US