University of Cape Coast Institutional Repository

Assessment of surface water quality status of the Aby Lagoon System in the Western Region of Ghana

Show simple item record

dc.contributor.author Miyittah, K. Michael
dc.contributor.author Tulashie, Samuel Kofi
dc.contributor.author Tsyawo, Francis W.
dc.contributor.author Sarfo, Justice K.
dc.contributor.author Darko, Archibald A.
dc.date.accessioned 2021-04-06T10:08:13Z
dc.date.available 2021-04-06T10:08:13Z
dc.date.issued 2020
dc.identifier.issn 23105496
dc.identifier.uri http://hdl.handle.net/123456789/5225
dc.description 11p:, ill. en_US
dc.description.abstract The pollution status of the Tendo Lagoon, the upstream section of the Aby Lagoon System, was investigated. The water temperature, pH, turbidity, dissolved oxygen (DO), electrical conductivity (EC), nitrates (NO-3), and phosphate (PO3-4 ) levels were evaluated using samples taken during the wet and dry seasons to assess the variabilities in water quality in the area. The water quality data was subjected to paired t-test, One-way ANOVA, Factor Analysis, Cluster analysis (CA) as well as a Water Quality Index (WQI) evaluation using the Canadian Council of Ministers of the Environment (CCME) model. The paired sample t-test confirmed that the surface water quality varies significantly between the wet and dry season samples (p < 0.05) except for phosphate loads which may be contributed largely by year-round municipal waste discharges. The results of the ANOVA showed that the variation of the water quality parameters among sampling stations was not statistically significant except for turbidity which was relatively higher in the upstream sections where the Tano River enters the lagoon. The results of FA indicated that three significant factors–relating to the degradation of organic materials, suspended solids (turbidity) and nutrients- accounted for 73.65% of spatio-temporal variations in the water quality. The CA showed that the eight sampling stations can be grouped into four distinct clusters based on their water quality. The source of pollution in the demarcated sections of the Aby Lagoon was concluded to be largely due to the result of localized anthropogenic inputs of domestic waste and sediments carried from the upstream in the Tano River. An evaluation of the CCME WQI for the sampling stations revealed that all the sampling stations showed marginal water quality relative to the target water quality range recommended by the Water Resources Commission (WRC) of Ghana for domestic use and protection of aquatic life. Monitoring programs were recommended with effective management measures instituted and implemented for the sustainability of the lagoon and the Tano River Basin en_US
dc.language.iso en en_US
dc.publisher University of Cape Coast en_US
dc.subject Factor analysis en_US
dc.subject Cluster analysis en_US
dc.subject Aby lagoon system en_US
dc.subject Surface water quality en_US
dc.subject Water quality index en_US
dc.subject Environmental analysis en_US
dc.subject Environmental hazard en_US
dc.subject Environmental health en_US
dc.subject Environmental management en_US
dc.subject Hydrology en_US
dc.subject Environmental science en_US
dc.title Assessment of surface water quality status of the Aby Lagoon System in the Western Region of Ghana en_US
dc.type Article en_US