University of Cape Coast Institutional Repository

Optimization Of Radiation Dose And Risk Assessment During Interventional Cardiology Procedures: A Case Study At The National Cardiothoracic Centre, Korle-Bu Teaching Hospital-Ghana

Show simple item record

dc.contributor.author AKROBORTU, EMMANUEL
dc.date.accessioned 2025-01-27T15:04:46Z
dc.date.available 2025-01-27T15:04:46Z
dc.date.issued 2023-08
dc.identifier.uri http://hdl.handle.net/123456789/11657
dc.description xviii,160p:, ill. en_US
dc.description.abstract Cardiac intervention procedures involve high radiation doses, hence the need to protect patients and staff from deterministic and stochastic effects. Patients’ weight, height, age, and radiation exposure values were measured at the National Cardiothoracic Centre (NCTC), where a number of different interventional cardiology procedures were performed. Body Mass Index (BMI) was calculated from measured weight and height results. Dose data were collected for a total of 498 patients: comprising of 309 males and 189 females. The values for Dose Area Product (DAP) were measured using DAP meter for four cardiovascular examinations namely, Coronary Angiography (CA), Percutaneous Coronary Intervention (PCI), combine Coronary Angiography and Percutaneous Coronary Intervention (CAPCI) and Right Heart Catheterization (RHC). Occupational doses (staff effective doses) were calculated using three different double dosimetry algorithms with two dosimeters (TLDs) that were placed above and below the lead protective apron. Staff total detriment to radiation was estimated using risk coefficients for stochastic effect and the results obtained are 1.76∗ 10−3 for surgeons 7.96∗ 10−4 for nurses and 1.29 ∗10−4 for operators. BMI obtained for females and males were (29.92±5.51) kg/m2 and (27.14±4.03) kg/m2, respectively. Male dose values obtained were [(17.34±12.62), (74.77±11.20), (87.17±10.72), (34.87±37.48)] μGycm2 and female dose values were [(69.44±76.15), (133.49±94.37), (80.90±10.78), (34.27±35.02)] μGycm2 for CA, PCI, CAPCI and RHC, respectively. Effective doses obtained ranged between [0.54-2.20), (0.45-1.61), (0.52-1.04)] mSv for cardiologists, nurses, and operators, respectively. en_US
dc.language.iso en en_US
dc.publisher University of Cape Coast en_US
dc.subject Algorithm, Angiography, Fluoroscopy, Interventional, Radiation, Phantom en_US
dc.title Optimization Of Radiation Dose And Risk Assessment During Interventional Cardiology Procedures: A Case Study At The National Cardiothoracic Centre, Korle-Bu Teaching Hospital-Ghana en_US