Measurement of odour in on-site sanitation systems in low-income settings

Show simple item record

dc.contributor.author Obeng, Peter Appiah
dc.contributor.author Oduro-Kwarteng, Sampson
dc.contributor.author Keraita, Bernard
dc.contributor.author Bregnhøj, Henrik
dc.contributor.author Abaidoo, Robert C
dc.contributor.author Awuah, Esi
dc.contributor.author Konradsen, Flemming
dc.date.accessioned 2021-07-28T10:23:28Z
dc.date.available 2021-07-28T10:23:28Z
dc.date.issued 2016-01-22
dc.identifier.issn 23105496
dc.identifier.uri http://hdl.handle.net/123456789/5768
dc.description 11p:, ill. en_US
dc.description.abstract The objective assessment of the level of odour in on-site sanitation systems is required when evaluating emerging technology options and maintenance practices. The purpose of this study was to measure the concentrations of hydrogen sulphide and ammonia as surrogates of odour using a portable gas detector, and assess whether the concentrations of the compounds correlate with the perception of users of the facilities. The Aeroqual 500 portable gas detector with hydrogen sulphide and ammonia sensor heads was used to measure the concentrations of the compounds in 88 rivate and seven communal latrines sampled from a peri-urban community in Ghana. The odour perception of 189 and 165 users of private and communal latrines, respectively, was assessed on an ordinal scale. It was found that the concentrations of hydrogen sulphide and ammonia measured with the gas detector reflected the known variation of odour levels among different technology options and the perceptions of the latrine users. The concentrations of hydrogen sulphide measured in the water closet, ventilated improved it (VIP) and the simple it latrines were 0.01, 0.03 and 0.13 pm, respectively; those of ammonia were undetected for the water closet, and 0.30 and 3.27 pm for the VIP and simple it latrines, respectively. The Pearson correlation coefficient between hydrogen sulphide concentrations and user perception of odour (−0.234) was significant at 5 % level (p = 0.022) but that for ammonia was not. The results indicate that a ortable hydrogen sulphide detector may be employed to objectively assess the effectiveness of new latrine designs and maintenance ractices aimed at reducing odour in latrines en_US
dc.language.iso en en_US
dc.publisher University of Cape Coast en_US
dc.subject Odour measurement en_US
dc.subject Odour perception en_US
dc.subject Latrine en_US
dc.subject On-site sanitation en_US
dc.subject Ghana en_US
dc.title Measurement of odour in on-site sanitation systems in low-income settings en_US
dc.type Article en_US